Troubleshooting UCCE peripheral gateways and CTI Server going offline

Verified 2026-10-02 · 59 sources · tier 2

Also known as ucce-pg-isolated-enabled, ucce-pg-troubleshooting.

A Unified CCE Peripheral Gateway (PG) talks to the Router using Device Management Protocol, and its OPC process runs in lock-step with its duplex sibling through MDS 30 25. Cisco identifies mismatched PG port assignments between the two servers of a duplex pair as a typical cause of a PG remaining isolated-enabled, and Finesse treats the CTI connection as lost when it misses 3 consecutive CTI Server heartbeats or its socket to the CTI Server fails 18 8.

How the PG and CTI Server fit together

The PG talks to the Router (central controller) using Device Management Protocol, and messages to OPC pass through the MDS queue to keep the duplex sides in lock-step 30. The OPC computes and maintains agent state on the PG and reports it to the Router 25. The PIM is not a lock-step process and shares no data between sides, so for each peripheral either the side A or the side B PIM is active 42. The JTAPI Gateway connects to the Unified CM CTI Manager and links the PG to the Unified CM cluster 19. Only the side A or the side B CTI Server is active at a time, never both 1.

An Agent PG connects to the Unified CM cluster through a single CTI Manager, so if that CTI Manager fails the PG cannot talk to the cluster 34. Cisco states that this is why it designs Agent PGs as a redundant pair 34. Agent PG side A signs in to the primary CTI Manager, and Agent PG side B signs in to the secondary CTI Manager on a different subscriber 37. Only one PG of the pair registers and monitors phones and CTI route points 57. The redundant PG runs in hot standby and signs in to its CTI Manager only to initialise the interface for failover 57.

Heartbeats and failure states

Duplexed UCCE sides exchange private-network heartbeats every 100 ms in both directions 46. If either side misses heartbeats for 5 times the heartbeat period, it assumes the private link or the peer has failed 47. Public-network heartbeats between each PG and the Central Controller run every 400 ms in both directions 54.

When the private network fails, a Router that has device majority goes to the isolated-enabled state and keeps handling traffic 17. A Router without device majority goes to the isolated-disabled state and stops processing traffic 16. During a private network failure, the pair-disabled Router side tells its enabled PGs to contact the other Router over the public network to test that side's status 58. When the public path to one Router is lost, PGs realign their data stream to their local Router, which forwards the data to the other Router over the private network 33.

Ports to check

UCCE PG port numbers shift by 40 per ICM instance, so the port for instance n equals the instance-0 port plus 40 times n 44. PG port ranges follow installation order on the host rather than the PG number 14. If PG2 is installed before PG1 on a server, PG2's processes take the 43xxx range and PG1 is given the 45xxx range 14.

Every port in the table below except the JTAPI row is the instance-0 value, to which 40 times the instance number is added 35 36 26 38 55 2.

Function TCP port Source
PG1 MDS private network (side A and B), low / medium / high 43004 / 43016 / 43005 35
PG2 MDS private network (side A and B), low / medium / high 45004 / 45016 / 45005 36
OPC state transfer, PG1 / PG2 43023 / 45023 26
PG Agent Test Other Side, PG1 / PG2 43006 / 45006 38
Router DMP public-low reached by PGs, side A / side B 40002 / 41002 55
Unsecured GED-188 CTI Server, side A / side B 42027 / 43027 2
CTI/QBE and JTAPI, PG to Unified CM CTI Manager 2748 20

Diagnosing a duplex PG that stays isolated-enabled

Cisco identifies mismatched PG port assignments between the two servers of a duplex pair as a typical cause of a PG remaining in the isolated-enabled state, especially after a fresh install or upgrade 18. Cisco attributes these mismatches to existing ICM installations, or remnants of them, on the servers 45. The ICM instance number is stored in the registry under the customer instance's CurrentVersion key 15. That instance number must match on both PGs of a pair, and a mismatch prevents the pair from forming duplex 15. The PG DMP system ID must also be the same on both PGs for the pair to form duplex 4.

WarmTransfer's reading of the sources is that, for a duplex PG that will not leave isolated-enabled after install or upgrade, checking that the instance number, DMP system ID and MDS/OPC ports match on both sides is a cheaper first step than log analysis 59.

Diagnosing a new PIM that stays idle

When a new PIM is added to a duplex PG while services are still active on one side, the new PIM can stay idle on both PGs and never try to connect to its peripheral 41. This happens because duplex synchronization copies the still-running partner's in-memory configuration back over the edited side, disabling the PIM the partner does not know about 39.

Cisco's fix has these steps 40:

  • Stop services on both PGs 40.
  • Remove the newly added PIMs 40.
  • Re-add the PIMs on both PGs while services are stopped 40.
  • Start services in either order and confirm the PIMs go active 40.

Cisco requires that any change to PG configuration is made while services are stopped on both PGs of the duplex pair 29.

Inspecting live PG and CTI Server processes

OPCTest is started on the PG with opctest /cust <instance> /node <PG node name>, and its status command shows the health and state of the PG 28.

In procmon attached to the PIM, dperiph shows the PIM status and how long it has been in its current state 49. In the same session, la lists configured agents with their current status and lc lists the active calls on the PIM 52.

In procmon attached to the JTAPI Gateway, jli lists every monitored device and its registration state, and jdi dumps one device's details 50. In the same session, jtapiver reports the JTAPI client version and jrever reports the JRE version 51.

In procmon attached to the CTI Server (ctisvr), clients lists all connected CTI clients, and dclient shows a client's connection status, IP address and port 48.

Collecting traces and logs

PG process logs live under C:\icm\<instance>\<PG name>\logfiles, and CTI Server logs live under C:\icm\<instance>\<CG name>\logfiles 31. PG process logs are extracted with dumplog, for example dumplog opc /bt 09:00 /et 09:30 /ms /o 5. In that command, /bt and /et set the begin and end time, /ms adds milliseconds, and /o writes to the default output file 5.

CTI Server tracing is raised by setting EMSTraceMask to f8 under the CG's EMS\CurrentVersion\library\Processes\ctisvr registry key 3. Unified CM PIM and VRU PIM tracing is enabled in procmon with commands such as trace tp* /on, trace precall /on, trace *event /on and trace csta* /on, and is reset with trace * /off 43.

From UCCE 8.0, the Unified System CLI command show tech-support absdatetime <start> <end> redirect dir <path> gathers logs from Router, Logger, PG and CVP servers in one pass 56.

What Finesse shows when the CTI Server goes offline

Finesse treats the CTI connection as lost when it misses 3 consecutive CTI Server heartbeats at a 5-second interval, or when its socket to the CTI Server fails 8. While CTI failover is in progress, Finesse is OUT_OF_SERVICE, sends no events, and answers client requests with 503 Service Unavailable 11. In duplex mode, Finesse alternates between the configured side A and side B CTI servers until a connection succeeds 7. Finesse CTI failover requires Unified CCE in duplex mode and the side B CTI host and port set in the Finesse administration console 6.

After reconnecting and returning to IN_SERVICE, Finesse publishes the last call-control, call-data and agent states to all clients 13. Events for a call that started and ended entirely during failover are not published 13.

With Agent PG 12.5(1) or later, Cisco puts CTI Server/Agent PG failover as seen by Finesse at roughly 35 to 75 seconds, excluding server recovery time 9. With Agent PG 12.0(1) or 11.6(1), Cisco puts CTI failover at roughly 75 to 120 seconds 10. With those older Agent PG releases, Finesse takes up to 40 seconds longer to detect CTI failover than with Agent PG 12.5(1) or later 10. Agent PG maintenance mode lets Finesse reconnect to the alternate PG without interrupting sign-in, state changes or calls 32.

On CTI disconnection, Finesse moves agents to WORK on non-voice media routing domains to stop task routing 21. Unified CCE can keep those agents in WORK after reconnect, and the enableAutoWorkModeStateChange property defaults to true 21.

We infer that an entire Finesse cluster going OUT_OF_SERVICE at once, while Unified CM phones keep working, points to the Agent PG CTI Server or the path to it rather than to Finesse itself 12.

Router errors tied to PG configuration

If the routing client's PG has no network VRU, the router log shows an error like No NetworkVRU configured for peripheral for VRU capable call when a Send to VRU or Run Ext Script node runs 23. For CVP comprehensive call flows, the network VRU must be Type 10 with a label for each routing client 24. The label length must match CVP's Maximum Length of DNIS setting 24.

See also

Applicability

Applies to: Cisco Unified Contact Center Enterprise, Cisco Finesse, and Cisco Unified Customer Voice Portal. Deployments: on-premises. Sources checked 2026-10-02. The JTAPI Gateway is present only in Unified CCE deployments 19. Finesse failover timings differ between Agent PG 12.5(1) or later and Agent PG 12.0(1) or 11.6(1) 9 10. Agent PG maintenance mode applies with Finesse 12.6(1) and Unified CCE 12.6(1) 32. Keeping agents in WORK on non-voice media routing domains after reconnect requires Unified CCE 12.5(1) or later 21. The Unified System CLI log collection command applies from UCCE 8.0 56.

What remains uncertain

Finesse republishes the last call-control, call-data and agent states after reconnecting, and maintenance mode avoids interrupting sign-in, state changes and calls 13 32. Beyond those 2 cases, the effect of an unplanned Agent PG failover on calls in progress and agent sign-in is not covered by the sources below. The jtapiver command reports the JTAPI client version on the PG 51. How a JTAPI client version mismatch on the PG behaves after a Unified CM upgrade is not covered by the sources below. How to place an Agent PG into maintenance mode on the UCCE side is not covered by the sources below. The CTI Manager failure detection timer seen by the JTAPI Gateway is not covered by the sources below. Logout on Agent Disconnect (LOAD) behaviour and defaults are not covered by the sources below. The unsecured GED-188 CTI Server ports are documented 2. The secured CTI Server port and the TLS CTI connection for Finesse are not covered by the sources below. OPCTest status output field labels on 12.x and 15.x are not covered by the sources below. The documented show tech-support command applies from UCCE 8.0 56. Current Unified System CLI and Diagnostic Framework log collection syntax is not covered by the sources below.

See also

Related to

Referenced by

Sources

  1. 1
    Only the side A or the side B CTI Server is active at a time, never both.
    Serviceability Guide for Cisco Unified Contact Center Enterprise, Release 15.0(1) - Product Architecture · Product Architecture; CTI Gateway (CTI Server) · Checked 2026-10-02
  2. 2
    The unsecured GED-188 CTI Server listens on TCP 42027 on side A and TCP 43027 on side B, each plus 40 times the instance number.
    Port Utilization Guide for Cisco Unified Contact Center Solutions, Release 12.6(2) - Port Utilization in Contact Center Enterprise · Table 4 Unified CCE Port Utilization: CTI and CTI Object Server; GED-188 CTI Server rows · Checked 2026-10-02
  3. 3
    CTI Server tracing is raised by setting EMSTraceMask to f8 under the CG's EMS\CurrentVersion\library\Processes\ctisvr registry key.
    Set and Collect UCCE Trace Logs · Setting traces; CTISVR · Checked 2026-10-02
  4. 4
    The PG DMP system ID must be the same on both PGs of a duplex pair for the pair to form duplex.
  5. 5
    PG process logs are extracted with dumplog, for example 'dumplog opc /bt 09:00 /et 09:30 /ms /o': /bt and /et set begin and end time, /ms adds milliseconds and /o writes to the default output file.
    Set and Collect UCCE Trace Logs · Collecting Logs; dumplog examples · Checked 2026-10-02
  6. 6
    Finesse CTI failover requires Unified CCE in duplex mode and the side B CTI host and port set in the Finesse administration console.
  7. 7
    In duplex mode, after losing the CTI Server Finesse alternates between the configured side A and side B CTI servers until a connection succeeds.
  8. 8
    Finesse treats the CTI connection as lost when it misses three consecutive CTI Server heartbeats (5-second interval) or when its socket to the CTI Server fails.
  9. 9
    With Agent PG 12.5(1) or later, Cisco puts CTI Server/Agent PG failover as seen by Finesse at roughly 35 to 75 seconds, excluding server recovery time.
  10. 10
    With Agent PG 12.0(1) or 11.6(1), Cisco puts CTI failover at roughly 75 to 120 seconds, and Finesse takes up to 40 seconds longer to detect CTI failover than with Agent PG 12.5(1) or later.
    Cisco Finesse Administration Guide, Release 15.0(1) - Cisco Finesse Failover Mechanisms · Failover Planning; CTI Failover and Guidelines for Optimal Desktop Failover; Agent PG Configuration · Checked 2026-10-02
  11. 11
    While CTI failover is in progress Finesse is OUT_OF_SERVICE, sends no events, and answers client requests with 503 Service Unavailable.
  12. 12
    An entire Finesse cluster going OUT_OF_SERVICE at once, while Unified CM phones keep working, points to the Agent PG CTI Server or the path to it rather than to Finesse itself.inferred
  13. 13
    After reconnecting and returning to IN_SERVICE, Finesse publishes the last call-control, call-data and agent states to all clients, but events for a call that started and ended entirely during failover are not published.
  14. 14
    PG port ranges follow installation order on the host rather than the PG number: if PG2 is installed before PG1 on a server, PG2's processes take the 43xxx range and PG1 is given the 45xxx range.
  15. 15
    The ICM instance number, stored in the registry under the customer instance's CurrentVersion key, must match on both PGs of a pair; a mismatch prevents the pair from forming duplex.
  16. 16
    When the private network fails, a Router without device majority goes to the isolated-disabled state and stops processing traffic.
  17. 17
    When the private network fails, a Router that has device majority goes to the isolated-enabled state and keeps handling traffic.
    Solution Design Guide for Cisco Unified Contact Center Enterprise, Release 12.6(1) - High Availability and Network Design · Unified CCE Failovers During Network Failures; Response to Private Network Failures · Checked 2026-10-02
  18. 18
    Cisco identifies mismatched PG port assignments between the two servers of a duplex PG pair as a typical cause of a PG remaining in the isolated-enabled state, especially after a fresh install or upgrade.
  19. 19
    The JTAPI Gateway, present only in Unified CCE deployments, connects to the Unified CM CTI Manager and links the PG to the Unified CM cluster.
  20. 20
    The Cisco port utilization guide lists TCP 2748 for CTI/QBE and JTAPI communication between the PG and Unified CM CTI Manager.
  21. 21
    On CTI disconnection, Finesse moves agents to WORK on non-voice media routing domains to stop task routing, and Unified CCE 12.5(1) or later can keep them in WORK after reconnect; the enableAutoWorkModeStateChange property defaults to true.
    Cisco Finesse Administration Guide, Release 15.0(1) - Cisco Finesse Failover Mechanisms · Prevent Non-Voice Task RONAs during CTI Reconnect · Checked 2026-10-02
  22. 22
    The router resolves the network VRU through the dialed number's customer; the related router messages are 'Customer not found for dialed number', 'No network VRU is configured' and 'No label configured on network VRU'.
    CVP "Send to VRU" and "Run Ext Script" Failures · Router log checks · Checked 2026-10-02
  23. 23
    If the routing client's PG has no network VRU, the router log shows 'No NetworkVRU configured for peripheral for VRU capable call' when a Send to VRU or Run Ext Script node runs.
    CVP "Send to VRU" and "Run Ext Script" Failures · Router log checks · Checked 2026-10-02
  24. 24
    For CVP comprehensive call flows, the network VRU must be Type 10 with a label for each routing client, and the label length must match CVP's Maximum Length of DNIS setting.
    CVP "Send to VRU" and "Run Ext Script" Failures · Network VRU configuration checklist · Checked 2026-10-02
  25. 25
    The OPC computes and maintains agent state on the PG, reports it to the Router, and runs in lock-step with its duplex sibling through MDS.
    Serviceability Guide for Cisco Unified Contact Center Enterprise, Release 15.0(1) - Product Architecture · Product Architecture; Open Peripheral Controller · Checked 2026-10-02
  26. 26
    The OPC state-transfer port is TCP 43023 for PG1 and TCP 45023 for PG2, each plus 40 times the instance number.
  27. 27
    OPCTest status output includes PGAgent status, such as CONNECTED or IDLE, with the last state-change time and the times of connection to the side A and side B Routers.
    Using the OPCTest Command-Line Utility · status command output · Checked 2026-10-02
  28. 28
    OPCTest is started on the PG with 'opctest /cust <instance> /node <PG node name>', and its status command shows the health and state of the PG.
    Using the OPCTest Command-Line Utility · Start OPCTest; status command · Checked 2026-10-02
  29. 29
    Cisco requires that any change to PG configuration is made while services are stopped on both PGs of the duplex pair.
    UCCE PIM Failure when Added to PGs in Duplex Mode · Solution, note · Checked 2026-10-02
  30. 30
    The PG talks to the Router (central controller) using Device Management Protocol, and messages to OPC pass through the MDS queue to keep duplex sides in lock-step.
  31. 31
    PG process logs live under C:\icm\<instance>\<PG name>\logfiles and CTI Server logs under C:\icm\<instance>\<CG name>\logfiles.
    Set and Collect UCCE Trace Logs · Collecting Logs; log locations · Checked 2026-10-02
  32. 32
    With Finesse 12.6(1) and Unified CCE 12.6(1), Agent PG maintenance mode lets Finesse reconnect to the alternate PG without interrupting sign-in, state changes or calls.
    Cisco Finesse Administration Guide, Release 15.0(1) - Cisco Finesse Failover Mechanisms · Maintenance Mode; Agent PG Maintenance Mode · Checked 2026-10-02
  33. 33
    When the public path to one Router is lost, PGs realign their data stream to their local Router, which forwards data to the other Router over the private network.
  34. 34
    An Agent PG connects to the Unified CM cluster through a single CTI Manager, so if that CTI Manager fails the PG cannot talk to the cluster; that is why Cisco designs Agent PGs as a redundant pair.
  35. 35
    For PG1 (side A and B), the MDS private-network ports are TCP 43004 (low), 43016 (medium) and 43005 (high), each plus 40 times the instance number.
    Port Utilization Guide for Cisco Unified Contact Center Solutions, Release 12.6(2) - Port Utilization in Contact Center Enterprise · Table 1 Unified CCE Port Utilization: Routers, PGs, Administration & Data Servers, and Loggers; ICM PG1 rows · Checked 2026-10-02
  36. 36
    For PG2 (side A and B), the MDS private-network ports are TCP 45004 (low), 45016 (medium) and 45005 (high), each plus 40 times the instance number.
  37. 37
    Agent PG side A signs in to the primary CTI Manager and Agent PG side B signs in to the secondary CTI Manager on a different subscriber.
  38. 38
    The PG Agent Test Other Side port is TCP 43006 for PG1 and TCP 45006 for PG2, each plus 40 times the instance number.
  39. 39
    The idle-PIM failure happens because duplex synchronization copies the still-running partner's in-memory configuration back over the edited side, disabling the PIM the partner does not know about.
  40. 40
    Cisco's fix for an idle new PIM: stop services on both PGs, remove the newly added PIMs, re-add them on both PGs while services are stopped, then start services in either order and confirm the PIMs go active.
    UCCE PIM Failure when Added to PGs in Duplex Mode · Solution, steps 1-6 · Checked 2026-10-02
  41. 41
    When a new PIM is added to a duplex PG while services are still active on one side, the new PIM can stay idle on both PGs and never try to connect to its peripheral.
    UCCE PIM Failure when Added to PGs in Duplex Mode · Problem · Checked 2026-10-02
  42. 42
    The PIM is not a lock-step process and shares no data between sides; for each peripheral either the side A or the side B PIM is active.
    Serviceability Guide for Cisco Unified Contact Center Enterprise, Release 15.0(1) - Product Architecture · Product Architecture; Peripheral Interface Manager · Checked 2026-10-02
  43. 43
    Unified CM PIM and VRU PIM tracing is enabled in procmon with commands such as 'trace tp* /on', 'trace precall /on', 'trace *event /on' and 'trace csta* /on', and reset with 'trace * /off'.
    Set and Collect UCCE Trace Logs · Setting traces; procmon · Checked 2026-10-02
  44. 44
    UCCE PG port numbers shift by 40 per ICM instance: the port for instance n equals the instance-0 port plus 40 times n.
  45. 45
    Cisco attributes PG port mismatches between pairing servers to existing ICM installations, or remnants of them, on the servers.
  46. 46
    Duplexed UCCE sides exchange private-network heartbeats every 100 ms in both directions.
    Solution Design Guide for Cisco Unified Contact Center Enterprise, Release 12.6(1) - High Availability and Network Design · Network Design for Reference Design Compliant Solutions · Checked 2026-10-02
  47. 47
    If either side misses heartbeats for five times the heartbeat period, it assumes the private link or peer has failed.
    Solution Design Guide for Cisco Unified Contact Center Enterprise, Release 12.6(1) - High Availability and Network Design · Network Design for Reference Design Compliant Solutions · Checked 2026-10-02
  48. 48
    In procmon attached to the CTI Server (ctisvr), clients lists all connected CTI clients and dclient shows a client's connection status, IP address and port.
    Troubleshoot ICM with ProcMon Utility Commands for PG Processes · Computer Telephony Integration Server · Checked 2026-10-02
  49. 49
    In procmon attached to the PIM, the dperiph command shows the PIM status and how long it has been in its current state.
    Troubleshoot ICM with ProcMon Utility Commands for PG Processes · Agent Peripheral Interface Manager · Checked 2026-10-02
  50. 50
    In procmon attached to the JTAPI Gateway, jli lists every monitored device and its registration state, and jdi dumps one device's details.
    Troubleshoot ICM with ProcMon Utility Commands for PG Processes · Java Gateway Process · Checked 2026-10-02
  51. 51
    In procmon attached to the JTAPI Gateway, jtapiver reports the JTAPI client version and jrever reports the JRE version.
    Troubleshoot ICM with ProcMon Utility Commands for PG Processes · Java Gateway Process · Checked 2026-10-02
  52. 52
    In procmon attached to the PIM, la lists configured agents with their current status and lc lists the active calls on the PIM.
    Troubleshoot ICM with ProcMon Utility Commands for PG Processes · Agent Peripheral Interface Manager · Checked 2026-10-02
  53. 53
    In a split public-network failure where an agent's phone is registered on the far side of the Unified CM cluster, Unified CCE can no longer direct calls to the phone and automatically signs the agent out.
  54. 54
    Public-network heartbeats between each PG and the Central Controller run every 400 ms in both directions.
    Solution Design Guide for Cisco Unified Contact Center Enterprise, Release 12.6(1) - High Availability and Network Design · Network Design for Reference Design Compliant Solutions · Checked 2026-10-02
  55. 55
    PGs reach the Router's DMP public-low port on TCP 40002 for side A and TCP 41002 for side B, each plus 40 times the instance number.
  56. 56
    From UCCE 8.0 the Unified System CLI command 'show tech-support absdatetime <start> <end> redirect dir <path>' gathers logs from Router, Logger, PG and CVP servers in one pass.
    Set and Collect UCCE Trace Logs · Using Diagnostic Framework/CLI · Checked 2026-10-02
  57. 57
    Only one PG of the pair registers and monitors phones and CTI route points; the redundant PG runs in hot standby, signed in to its CTI Manager only to initialise the interface for failover.
  58. 58
    During a private network failure, the pair-disabled Router side tells its enabled PGs to contact the other Router over the public network to test that side's status.
  59. 59
    For a duplex PG that will not leave isolated-enabled after install or upgrade, checking that instance number, DMP system ID and MDS/OPC ports match on both sides is a cheaper first step than log analysis.inferred
    Unified Contact Center Enterprise (UCCE) Peripheral Gateway (PG) TCP Port Range Assignment and duplex operations · Conclusion; combined with Port Utilization Guide Table 1 · Checked 2026-10-02

Documents

tier 2 current vendor documentation

Cisco Finesse Administration Guide, Release 15.0(1) - Cisco Finesse Failover Mechanisms

Cisco Systems · 2026-07-24 · accessed 2026-10-02

tier 2 current vendor documentation

CVP "Send to VRU" and "Run Ext Script" Failures

Cisco Systems · 2013-09-23 · accessed 2026-09-30

tier 2 current vendor documentation

Serviceability Guide for Cisco Unified Contact Center Enterprise, Release 15.0(1) - Product Architecture

Cisco Systems · 2025-04-30 · accessed 2026-10-02

tier 2 current vendor documentation

Set and Collect UCCE Trace Logs

Cisco Systems · 2018-01-03 · accessed 2026-10-02

tier 2 current vendor documentation

Solution Design Guide for Cisco Unified Contact Center Enterprise, Release 12.6(1) - High Availability and Network Design

Cisco Systems · 2021-05-14 · accessed 2026-10-02

tier 2 current vendor documentation

Troubleshoot ICM with ProcMon Utility Commands for PG Processes

Cisco Systems · 2018-08-24 · accessed 2026-10-02

tier 2 current vendor documentation

UCCE PIM Failure when Added to PGs in Duplex Mode

Cisco Systems · 2018-05-15 · accessed 2026-10-02

tier 2 current vendor documentation

Unified Contact Center Enterprise (UCCE) Peripheral Gateway (PG) TCP Port Range Assignment and duplex operations

Cisco Systems · 2017-02-07 · accessed 2026-10-02

tier 2 current vendor documentation

Using the OPCTest Command-Line Utility

Cisco Systems · 2006-10-01 · accessed 2026-10-02

Cite this page

APA

WarmTransfer. (2026, October 2). Troubleshooting UCCE peripheral gateways and CTI Server going offline. WarmTransfer. https://warmtransfer.net/knowledge/ucce-peripheral-gateway-troubleshooting

BibTeX

@misc{warmtransfer-ucce-peripheral-gateway-troubleshooting,
  title  = {Troubleshooting UCCE peripheral gateways and CTI Server going offline},
  author = {{WarmTransfer}},
  year   = {2026},
  url    = {https://warmtransfer.net/knowledge/ucce-peripheral-gateway-troubleshooting},
  note   = {Verified 2026-10-02}
}