Webex Contact Center integration connectors
Verified 2026-09-05 · 21 claims · sources tier 2
Also known as CCAI Config, Connector ID, Refresh Key.
WarmTransfer's reading of the sources is that Webex Contact Center integration connectors store authentication details that flow activities use to integrate with external systems 117. WarmTransfer's reading of the sources is that a connector governs credentials rather than destinations, as Flow Designer positions a connector as a common location to store credentials while permitting authors to disable authenticated endpoints and supply destination URLs directly 7.
Connector types across platform generations
The earlier Webex Contact Center 1.0 platform supports 2 connector types: Salesforce and Custom 5.
Documentation for the current platform contains 3 connector type lists that do not agree: an availability sentence listing 6 types, a configuration list containing 9 types, and a related-articles list linking to 8 entries 13. Specifically, Google is listed plain in the availability sentence but as Google TTS in the configuration list without clarifying whether they share the same connector record 14. Furthermore, ServiceNow, Microsoft Dynamics 365, and Microsoft Teams appear solely in the configuration list without inclusion in either availability sentence, and ServiceNow lacks a related-articles link altogether 14.
Configuration and lifecycle management
The section titled Configure a Connector contains only a list of connector names, omitting fields, steps, and procedures, deferring setup entirely to separate articles 2. Cisco does not state what fields a connector record holds, what format they take, or where underlying credentials reside, though an edit page provides a Credentials section 11. Furthermore, documentation names no roles, permissions, or entitlements needed to create, edit, deactivate, reactivate, or delete a connector 9. The connectors documentation also names no authentication scheme for any connector type, though Flow Designer lists Basic Auth and OAuth 2.0 for authenticated HTTP Request endpoints 8.
A connector's identifier cannot be modified after creation 3. To edit credentials, administrators must deactivate the connector first; deactivation does not immediately terminate active scripts, which may continue executing for some time while their credentials remain valid 4.
Specific connectors impose unique lifecycle constraints:
- Cisco describes the Salesforce connector as essentially creating the domain section of the URL for an HTTP Request activity 12.
- Editing or reactivating the Google Contact Center AI connector requires reauthenticating with Google, a refresh flow that must run outside business hours with browser pop-up blockers disabled 6.
- A Google Contact Center AI connector cannot be deleted while associated with a CCAI configuration, though the documentation never defines what a CCAI configuration is or where administrators manage it 1.
In Flow Designer, text-to-speech activities display only active connectors within their connector drop-down menus 10.
See also
- See also What each Webex Contact Center connector type stores.
- See also The Microsoft Dynamics 365 and Microsoft Teams connector entries.
- See also Webex Contact Center platform generations and predecessors.
- See also Webex Contact Center Flow Designer architecture.
- See also The Flow Designer virtual agent activities.
- See also Which Flow Designer activities can send customer data outside the platform.
Applicability
Across the claims in this article, the evidence covers Cisco Webex Contact Center, verified as of 2026-09-05. The deployment model is not covered by any claim in this article. Documentation covers the earlier Webex Contact Center 1.0 platform for its 2 supported connector types 5.
What remains uncertain
- The contents of the 8 per-connector-type articles deferred to by the overview are not covered by any claim in this article.
- What fields a connector record holds and where underlying credentials are stored are not covered by any claim in this article.
- Whether a flow author can enumerate connectors they are not entitled to use is not covered by any claim in this article.
- How long a deactivated connector keeps working for running scripts is not covered by any claim in this article.
See also
Constrained by
- Webex Contact Center platform generations and predecessors — The earlier platform supports two connector types
Depends on
- The Flow Designer virtual agent activitiesstub — The Google connector is the credential boundary behind Virtual Agent V2
Governs
- Which Flow Designer activities can send customer data outside the platform — The credential mechanism for three of the egress routes
Referenced by
- The Microsoft Dynamics 365 and Microsoft Teams connector entries — Two of the types the overview defers
- What each Webex Contact Center connector type stores — The per-type detail the overview defers
Claims
| # | Claim | Status | Confidence | Verified |
|---|---|---|---|---|
| 1 | A Google Contact Center AI connector cannot be deleted while a CCAI configuration is associated with it, and the article never defines what a CCAI configuration is or where it is managed. Set up integration connectors for Webex Contact Center · Edit a Connector, deactivated-connector options | fact | 0.90 | 2026-09-05 |
| 2 | The section titled Configure a Connector contains only a list of connector names, with no fields, no steps and no procedure; per-type setup is deferred entirely to separate articles. Set up integration connectors for Webex Contact Center · Configure a Connector, whole section | fact | 0.90 | 2026-09-05 |
| 3 | The connector identifier cannot be modified after creation. Set up integration connectors for Webex Contact Center · Edit a Connector, deactivated-connector options | fact | 0.90 | 2026-09-05 |
| 4 | A connector must be deactivated before its credentials can be edited, and deactivation does not immediately stop scripts already running, which may keep working for some time while their credentials remain valid. Set up integration connectors for Webex Contact Center · Edit a Connector, steps 2 and 3 | fact | 0.90 | 2026-09-05 |
| 5 | The article states that the earlier Webex Contact Center 1.0 platform supports 2 connector types, Salesforce and Custom. Set up integration connectors for Webex Contact Center · Availability of connectors | fact | 0.90 | 2026-09-05 |
| 6 | Editing or reactivating the Google Contact Center AI connector requires reauthenticating with Google, and the refresh flow is to be run outside business hours with the browser pop-up blocker disabled. Set up integration connectors for Webex Contact Center · Edit a Connector, step 2 and the deactivated-connector options | fact | 0.90 | 2026-09-05 |
| 7 | A connector governs credentials rather than destinations: the Flow Designer article describes a connector as a common location to store credentials, and the same activity lets a flow author turn off the authenticated-endpoint toggle and type a destination URL directly. Build and manage flows with Flow Designer · HTTP Request, Connector field and Use Authenticated Endpoint toggle | inference | 0.60 | 2026-09-05 |
| 8 | The connectors article names no authentication scheme for any connector type, while the Flow Designer article names Basic Auth and OAuth 2.0 for authenticated HTTP Request endpoints. Set up integration connectors for Webex Contact Center · Whole article; against the Flow Designer HTTP Request section | fact | 0.90 | 2026-09-05 |
| 9 | The article never names any role, permission or entitlement required to create, edit, deactivate, reactivate or delete a connector, and never says whether a flow author can enumerate connectors they are not entitled to use. Set up integration connectors for Webex Contact Center · Whole article | fact | 0.90 | 2026-09-05 |
| 10 | Flow Designer states that only active connectors appear in the connector drop-down of the text-to-speech activities. Build and manage flows with Flow Designer · Collect Digits, Menu and Play Message, Connector field | fact | 0.90 | 2026-09-05 |
| 11 | The article never states what fields a connector record holds, in what form, or where the underlying credential values are stored, although it names a Credentials section on the edit page. Set up integration connectors for Webex Contact Center · Edit a Connector; whole article | fact | 0.90 | 2026-09-05 |
| 12 | Cisco describes the Salesforce connector as essentially creating the domain section of the URL for an HTTP Request. Build and manage flows with Flow Designer · HTTP Request, Connector field description | fact | 0.90 | 2026-09-05 |
| 13 | The connectors article carries 3 lists of connector types that do not agree: an availability sentence naming 6 for the current platform, a configuration list naming 9, and a related-articles list of 8 links. Set up integration connectors for Webex Contact Center · Availability of connectors; Configure a Connector; Related Articles | fact | 0.90 | 2026-09-05 |
| 14 | In the connectors article, Google appears plain in the availability sentence but as Google TTS in the configuration list with no statement of whether they are the same connector; ServiceNow, Microsoft Dynamics 365 and Microsoft Teams appear in the configuration list but in neither availability sentence; and ServiceNow has no related-articles link at all. Set up integration connectors for Webex Contact Center · Availability of connectors; Configure a Connector; Related Articles | fact | 0.90 | 2026-09-05 |
| 15 | Cisco names a Webex Contact Center credential service, described as part of the Control Hub connector, which keeps the OAuth access token valid so that flow developers do not manage refresh. Configure custom connector for Webex Contact Center · Configure custom connector, password grant material | fact | 0.90 | 2026-09-05 |
| 16 | A custom connector record holds a name, an authentication type and a resource domain URL, and carries up to 2 secrets in one record depending on the grant chosen: a private key or certificate, a client secret, or a password. Configure custom connector for Webex Contact Center · Configure custom connector, authentication and grant fields | fact | 0.90 | 2026-09-05 |
| 17 | The connector overview links to the Microsoft Dynamics 365 article through an authoring preview address rather than a published one. Set up integration connectors for Webex Contact Center · Related Articles list, Microsoft Dynamics 365 entry | field-pattern | 0.90 | 2026-09-05 |
| 18 | A Google Contact Center AI connector record holds a name, a project name, a billable project name and a billable service account, and the administrator types no secret; authentication is a Google sign-in. Configure Google CCAI connector · Configure Google CCAI connector, record fields | fact | 0.90 | 2026-09-05 |
| 19 | The Google Contact Center AI connector article states no maximum number of connectors of this type. Configure Google CCAI connector · Configure Google CCAI connector, record fields | fact | 0.90 | 2026-09-05 |
| 20 | The HTTP connector article is the only one of the 5 per-type articles that publishes a role matrix, naming 6 roles with read and write access, 3 with no access and 1 with read-only access. Create Webex Contact Center HTTP connector · Create Webex Contact Center HTTP connector, role table | fact | 0.90 | 2026-09-05 |
| 21 | None of the 5 per-type connector articles states where a credential is stored, in what form, whether it is encrypted, or whether it can be read back. Configure custom connector for Webex Contact Center · All 5 per-type articles read in full; the overview's Credentials section named and never described | fact | 0.90 | 2026-09-05 |
Sources
Build and manage flows with Flow Designer
Configure custom connector for Webex Contact Center
Configure Google CCAI connector
Create Webex Contact Center HTTP connector
Set up integration connectors for Webex Contact Center
Cite this page
APA
WarmTransfer. (2026, September 5). Webex Contact Center integration connectors. WarmTransfer. https://warmtransfer.net/knowledge/wxcc-integration-connectors
BibTeX
@misc{warmtransfer-wxcc-integration-connectors,
title = {Webex Contact Center integration connectors},
author = {{WarmTransfer}},
year = {2026},
url = {https://warmtransfer.net/knowledge/wxcc-integration-connectors},
note = {Verified 2026-09-05}
}