Troubleshooting Unified CM database replication

Verified 2026-09-30 · 57 sources · tier 2

Also known as CUCM database replication, Unified CM Database Status report, utils dbreplication runtimestate.

Unified CM database replication operates in a fully meshed topology in which the publisher and every subscriber establish logical connections to all other servers in the cluster 7. Verifying and troubleshooting this replication topology relies on Command Line Interface (CLI) diagnostic utilities, system reports, and service checks 56​36​2.

Replication States and Verification

Replication health is verified by running utils dbreplication runtimestate on the first node (publisher), where each node should report a Connected replication status and a setup value of (2) Setup Completed 56. In the Replication Setup (RTMT) & Details column of the utils dbreplication runtimestate output, a value of 2 indicates replication is good 43. The 12.5(1)SU1 Administration Guide states that any Replication Setup value other than 2 indicates a problem with database replication 14. WarmTransfer's reading of the sources is that the meanings of setup values 0 through 4 appear unchanged between Release 12.5(1)SU1 and Release 15 55.

WarmTransfer's reading of the sources is that the documented replication setup values indicate specific states: 55

Value Documented meaning Detailed source description
0 Replication not started 40 The Release 15 Administration Guide attributes this to no subscribers existing or the Database Layer Monitor service not running 40; the TAC technote describes it as an initialization state where staying over an hour indicates a possible setup failure 41.
1 Replicates created but count incorrect 42 Replicates have been created, but their count is incorrect 42.
2 Replication good / Setup Completed 43​56 Connected status with Setup Completed across all nodes 56.
3 Replication bad in cluster / Mismatched tables 44​45 The Administration Guide defines this as replication being bad in the cluster 44; the TAC technote describes it as logical connections being established while table matches remain uncertain 45.
4 Setup failed / dropped 46​47 The Administration Guide defines this as setup not succeeding 46; the TAC technote describes it as a server lacking an active logical connection to receive tables 47.

Running utils dbreplication runtimestate requires command privilege level 0, is allowed during upgrade, and reports status from the perspective of a specific node when provided that node's name 35. In a healthy utils dbreplication runtimestate output, status checks show complete with no errors or mismatches, DB/RPC/DbMon reports Y/Y/Y for each server, the replication queue is typically 0, and setup displays Setup Completed for all servers 9. When reviewing utils dbreplication runtimestate, checking the timestamp prevents reading the Cluster Replication State section from outdated synchronization information 39.

To trigger a background check of replication, run utils dbreplication status on the first node (publisher), and review its progress and results via utils dbreplication runtimestate 48​49. The Release 15 CLI reference states that utils dbreplication status should run only on the publisher and is not allowed during an upgrade 49.

Prerequisites and Environmental Diagnostics

WarmTransfer's reading of the sources is that non-destructive checks across services, network connectivity, DNS, NTP, cluster authentication, and configuration files precede repair actions, while reset procedures remain a final resort 18.

Four specific services must display a STARTED state in the output of utils service list: Cluster Manager, A Cisco DB, A Cisco DB Replicator, and Cisco Database Layer Monitor 36.

Network and environment verification requires passing checks:

  • Diagnostic tests: When running utils diagnose test, validate_network, ntp_reachability, and ntp_stratum must all report Passed 3.
  • NTP configuration: The NTP stratum must be less than 5 to avoid being deemed unreliable 16. In utils ntp status, the publisher synchronizes to an external NTP server, and subscribers report the publisher as their synchronization source at 1 stratum level higher 17. The address-change troubleshooting chapter gives utils ntp status, utils ntp restart, and utils ntp server list as the NTP checks on both publisher and subscriber nodes 15.
  • DNS records: If DNS is configured on any Unified CM server, both forward and reverse records (such as A and PTR) are required 4. A failed reverse DNS lookup causes replication-related network diagnostic errors, which are checked using utils network eth0 all and utils network host 34.
  • Cluster authentication: If show network cluster reports nodes as unauthenticated, verify network connectivity and ensure the security password matches across all nodes 1. If a subscriber displays incorrect publisher details after an address change, update it using set network cluster publisher 37.
  • Network ports and latency: Intracluster database traffic requires 1500/TCP for the primary database connection, 1501/TCP for the secondary connection, and 8500 TCP/UDP for IPSec Cluster Manager intracluster system data replication 19​23. Port 1515/TCP is used for database replication during installation and must be permitted across the network to allow Database Layer RPC (DBL RPC) hello communication 20​21. Port 1516/TCP handles database replication during upgrade 22. Nodes spread over a WAN that show Out of Sync or Not Requested statuses require network latency well under 80 ms 57.
  • Hosts file consistency: The hosts, rhosts, and sqlhosts files must match across all nodes in the cluster, as reflected in the Unified CM Database Status report generated under Cisco Unified Reporting > System Reports > Unified CM Database Status 10​2. When this report flags a mismatch in those files, restart Cluster Manager and then A Cisco DB from the publisher CLI, generate a new report, and evaluate if the mismatch clears 11.

Remediation and Operational Procedures

When utils dbreplication runtimestate flags table mismatches or errors, running utils dbreplication repair all attempts resynchronization before a full reset is considered 29. The utils dbreplication repair command brings subscriber data into sync with the publisher and is permitted during an upgrade, whereas repairtable and repairreplicate do not repair replication setup 28. For clusters containing more than 8 nodes, Cisco TAC should be consulted before executing repair and reset steps (Steps 7 and 8) 53.

If a reset becomes necessary, utils dbreplication stop must first run on all subscriber nodes before executing utils dbreplication reset 50. In scenarios where cluster nodes are switched back to an older software version, replication must be manually reset by executing utils dbreplication reset all from the publisher CLI 51.

Additional CLI tuning and recovery options include:

  • utils dbreplication setprocess: Configures a process setting between 1 and 40 (default 1) to accelerate setup performance at the expense of higher system resource consumption 38.
  • utils dbreplication setrepltimeout: Configures replication timeout between 300 and 3600 seconds (default 300) to batch more subscriber servers on larger clusters 30. Sizing guidelines calculate timeout as 1 minute per server for nodes 1 through 5, 2 minutes per server for nodes 6 through 10, and 3 minutes per server beyond 10, totaling 21 minutes for a 12-server cluster 31.
  • utils dbreplication forcedatasyncsub: Replaces a subscriber's database with the publisher's data with a default recovery timeout of 40 minutes, but must not be executed if only dynamic tables are out of sync 6.
  • utils dbreplication rebuild: Can affect cluster performance across other nodes and is recommended to run within a maintenance window 27.

Prior to initiating an IP address or hostname change, verified health checks require confirming the absence of active ServerDown alerts, verifying a replication status of 2 for all nodes in utils dbreplication runtimestate, and executing utils diagnose module validate_network on the first node 24. Pre-upgrade manual workflows require running utils dbreplication status followed by utils dbreplication runtimestate, resolving any node not showing a replication setup value of 2 before upgrading 25. The Upgrade Readiness COP file checks authentication and replication status before and after a Release 15 upgrade 26.

When opening a TAC case regarding replication issues, Cisco asks for utils dbreplication runtimestate from the publisher, the Unified CM Database Status report, as well as show network cluster, show status, utils diagnose test, utils service list, utils network connectivity, show open ports all, and show open ports regexp 8500 gathered from the publisher and each affected subscriber 52​2.

See also

See also Unified CM backup and upgrade.

Applicability

Applies to: Cisco Unified Communications Manager. Deployments: on-premises. Sources checked 2026-09-30. The 12.5(1)SU1 Administration Guide addresses database replication verification rules 14. The Release 15 Administration Guide and CLI reference cover replication commands, port definitions, and setup states 40​35​20.

What remains uncertain

The field-by-field meaning of runtimestate output columns (Repl Queue, Replication Group ID g_N, DbMon, and PING) is not covered by the sources below. Known defects that break replication after an upgrade, certificate change, or IP change are not covered by the sources below. Resolving the dropadmindb conflict between a troubleshooting technote and the Release 15 CLI reference is not covered by the sources below. The exact node scope wording for reset and stop in the Release 15 CLI reference is not covered by the sources below. Reconciling the intracluster round-trip delay limit from the design guide against the 80 ms figure in the technote is not covered by the sources below. Procedures to rebuild a CUCM publisher from a subscriber are not covered by the sources below. The recovery procedure when the cluster security password does not match across nodes is not covered by the sources below. IM and Presence Service database replication troubleshooting is not covered by the sources below.

See also

Referenced by

Sources

  1. 1
    If show network cluster reports nodes as unauthenticated, the technote tells you to confirm network connectivity and that the security password is the same on all nodes.
    Troubleshoot CUCM Database Replication Issues · Step 5. Check the Connectivity Status from all the Nodes and Ensure They are Authenticated · Checked 2026-09-30
  2. 2
    The Unified CM Database Status report is generated at Cisco Unified Reporting > System Reports > Unified CM Database Status, and the technote advises downloading it so it can be given to a TAC engineer.
    Troubleshoot CUCM Database Replication Issues · Step 2. Collect the CM Database Status from the Cisco Unified Reporting Page on CUCM · Checked 2026-09-30
  3. 3
    In utils diagnose test output, the components that matter for replication are validate_network, ntp_reachability and ntp_stratum, and all three should show Passed.
    Perform a Health Check of CUCM Database Replication · Connectivity Verification, utils diagnose test · Checked 2026-09-30
  4. 4
    If DNS is configured anywhere on the Unified CM servers, the Administration Guide requires both forward and reverse records (for example A and PTR) to be configured.
    Administration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Pre-Change Tasks and System Health Checks · Pre-Change Tasks for Cisco Unified Communications Manager Nodes · Checked 2026-09-30
  5. 5
    The Release 15 CLI reference says utils dbreplication dropadmindb should be run only if a database replication reset or cluster reset fails.disputed
  6. 6
    utils dbreplication forcedatasyncsub erases a subscriber's data and replaces it with the publisher database, has a default recovery timeout of 40 minutes, and should not be run if only dynamic tables are out of sync.
    Command Line Interface Reference Guide for Cisco Unified Communications Solutions, Release 15 and SUs - Utils Commands · utils dbreplication forcedatasyncsub > Syntax Description and Usage Guidelines · Checked 2026-09-30
  7. 7
    Unified CM database replication is a fully meshed topology in which the publisher and every subscriber connect logically to every other server in the cluster.
    Perform a Health Check of CUCM Database Replication · Background Information · Checked 2026-09-30
  8. 8
    The Administration Guide repair procedure runs utils dbreplication repair all on the first node, monitors with runtimestate, lists utils dbreplication reset all to reestablish replication, and verifies that all nodes show (2) Setup Complete.
    Administration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Troubleshooting Address Change Issues · Troubleshoot Database Replication > Repair Database Replication, Steps 1-4 · Checked 2026-09-30
  9. 9
    The health-check technote shows a healthy runtimestate output as a completed status check with no errors or mismatches found, DB/RPC/DbMon of Y/Y/Y for every server, a replication queue typically at 0, and Setup Completed for every server.
    Perform a Health Check of CUCM Database Replication · Database Commands, utils dbreplication runtimestate sample output · Checked 2026-09-30
  10. 10
    The hosts, rhosts and sqlhosts files must match across all nodes in the cluster, and their equivalence is shown in the Unified CM Database Status report in Cisco Unified Reporting.
    Perform a Health Check of CUCM Database Replication · Hosts/Rhosts/Sqlhosts Files · Checked 2026-09-30
  11. 11
    When the database status report flags a hosts, rhosts or sqlhosts mismatch, the technote has you restart Cluster Manager and then A Cisco DB from the publisher CLI, generate a new report, and go to the reset step if the mismatch has cleared.
    Troubleshoot CUCM Database Replication Issues · Step 3. Review the Unified CM Database Report of any Component Flagged as an Error · Checked 2026-09-30
  12. 12
    The technote warns that incorrect activity is possible when an IP address changes or a hostname is updated, and points to the IP Address and Hostname Changes guide for the procedure.
    Troubleshoot CUCM Database Replication Issues · Step 3. Review the Unified CM Database Report of any Component Flagged as an Error · Checked 2026-09-30
  13. 13
    The Release 15 CLI reference marks utils dbreplication reset, stop, dropadmindb, rebuild, forcedatasyncsub, setprocess and setrepltimeout as not allowed during upgrade.
    Command Line Interface Reference Guide for Cisco Unified Communications Solutions, Release 15 and SUs - Utils Commands · Requirements block (Allowed during upgrade) under each named utils dbreplication command · Checked 2026-09-30
  14. 14
    The 12.5(1)SU1 Administration Guide states that any Replication Setup value other than 2 means there is a problem with database replication.
    Administration Guide for Cisco Unified Communications Manager, Release 12.5(1)SU1 - Troubleshooting Address Change Issues · Troubleshoot Database Replication > Verify Database Replication · Checked 2026-09-30
  15. 15
    The address-change troubleshooting chapter gives utils ntp status, utils ntp restart and utils ntp server list as the NTP checks on both publisher and subscriber nodes.
    Changing the IP Address and Hostname for Cisco Unified Communications Manager and IM and Presence Service, Release 12.5(1) - Troubleshooting Address Change Issues · Network Time Protocol troubleshooting > Troubleshoot NTP on Subscriber Nodes; Troubleshoot NTP on Publisher Nodes · Checked 2026-09-30
  16. 16
    The technote states that the NTP stratum must be less than 5, otherwise the time source is deemed unreliable.
    Troubleshoot CUCM Database Replication Issues · Step 4. Check the Individual Components that Use the Utils Diagnose Test Command, NTP Reachability · Checked 2026-09-30
  17. 17
    In utils ntp status, the publisher shows itself synchronized to an external NTP server, and subscribers show the publisher as their NTP source at one stratum level higher.
    Perform a Health Check of CUCM Database Replication · Connectivity Verification, utils ntp status · Checked 2026-09-30
  18. 18
    Cisco's troubleshooting order puts non-destructive checks (services, network, DNS, NTP, cluster authentication, hosts-file equivalence) ahead of repair, and repair ahead of reset, so a reset is the last resort and not the first response to a state other than 2.inferred
    Troubleshoot CUCM Database Replication Issues · Steps to Diagnose the Database Replication, Step 1 through Step 8 ordering · Checked 2026-09-30
  19. 19
    The Release 15 port-usage table lists 1500/TCP and 1501/TCP between Unified CM database nodes for the database connection, with 1501 as the secondary connection.
    System Configuration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Cisco Unified Communications Manager TCP and UDP Port Usage · Intracluster Ports Between Cisco Unified Communications Manager Servers, row 1500, 1501 / TCP · Checked 2026-09-30
  20. 20
    The Release 15 port-usage table lists 1515/TCP between Unified CM database nodes for database replication between nodes during installation.
    System Configuration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Cisco Unified Communications Manager TCP and UDP Port Usage · Intracluster Ports Between Cisco Unified Communications Manager Servers, row 1515 / TCP · Checked 2026-09-30
  21. 21
    The technote says port 1515 must be allowed on the network between nodes, in the context of confirming that the Database Layer RPC (DBL RPC) hello succeeds.
    Troubleshoot CUCM Database Replication Issues · Step 5. Check the Connectivity Status from all the Nodes and Ensure They are Authenticated · Checked 2026-09-30
  22. 22
    The Release 15 port-usage table lists 1516/TCP between Unified CM database nodes for database replication between nodes during upgrade.
    System Configuration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Cisco Unified Communications Manager TCP and UDP Port Usage · Intracluster Ports Between Cisco Unified Communications Manager Servers, row 1516 / TCP · Checked 2026-09-30
  23. 23
    The Release 15 port-usage table lists 8500 TCP and UDP between Unified CM nodes for intracluster replication of system data by the IPSec Cluster Manager.
    System Configuration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Cisco Unified Communications Manager TCP and UDP Port Usage · Intracluster Ports Between Cisco Unified Communications Manager Servers, row 8500 / TCP and UDP · Checked 2026-09-30
  24. 24
    Before an IP address or hostname change, the Administration Guide health check confirms there are no active ServerDown alerts, then that utils dbreplication runtimestate shows a status of 2 for all nodes, then runs utils diagnose module validate_network on the first node.
    Administration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Pre-Change Tasks and System Health Checks · Pre-Change Tasks for Cisco Unified Communications Manager Nodes, system health check steps · Checked 2026-09-30
  25. 25
    The Release 15 manual pre-upgrade tasks run utils dbreplication status and then utils dbreplication runtimestate, and require any node whose replication setup value is not 2 to be resolved before the upgrade proceeds.
  26. 26
    The Upgrade Readiness COP file checks database authentication and replication status both before and after a Release 15 upgrade.
    Upgrade and Migration Guide for Cisco Unified Communications Manager and the IM and Presence Service, Release 15 and SUs - Upgrade Tasks · Run Upgrade Readiness COP File (Pre-upgrade); Run Upgrade Readiness COP File (Post-upgrade) · Checked 2026-09-30
  27. 27
    The CLI reference warns that utils dbreplication rebuild can affect the performance of other nodes in the cluster and recommends running it during a maintenance window.
  28. 28
    Per the Release 15 CLI reference, utils dbreplication repair brings subscriber data back in sync with the publisher and is allowed during upgrade, while repairtable and repairreplicate do not repair replication setup.
    Command Line Interface Reference Guide for Cisco Unified Communications Solutions, Release 15 and SUs - Utils Commands · utils dbreplication repair; utils dbreplication repairtable; utils dbreplication repairreplicate > Usage Guidelines and Requirements · Checked 2026-09-30
  29. 29
    The technote uses utils dbreplication repair all when runtimestate shows errors or mismatched tables, and moves on to a full reset only if the status does not change.
    Troubleshoot CUCM Database Replication Issues · Step 7. Repair All/Selective Tables for Database Replication · Checked 2026-09-30
  30. 30
    utils dbreplication setrepltimeout accepts 300 to 3600 seconds with a default of 300, and raising it on large clusters lets more subscriber servers be included in the replication setup batch.
    Command Line Interface Reference Guide for Cisco Unified Communications Solutions, Release 15 and SUs - Utils Commands · utils dbreplication setrepltimeout > Syntax Description and Usage Guidelines · Checked 2026-09-30
  31. 31
    The technote sizes the replication timeout at 1 minute per server for servers 1 to 5, 2 minutes per server for servers 6 to 10, and 3 minutes per server beyond 10, giving 21 minutes for a 12-server cluster.
    Troubleshoot CUCM Database Replication Issues · Step 6. The Utils Dbreplication Runtimestate Command Shows out of Sync or not Requested Statuses, replication timeout · Checked 2026-09-30
  32. 32
    To reset replication for a single subscriber, the technote runs utils dbreplication stop for that subscriber from the publisher, utils dbreplication dropadmindb on the affected subscriber, then utils dbreplication reset for that subscriber from the publisher.
    Troubleshoot CUCM Database Replication Issues · Step 8. Reset the Database Replication from Scratch, single-node sequence · Checked 2026-09-30
  33. 33
    The technote's cluster-wide reset from scratch is: utils dbreplication stop all on the publisher only, utils dbreplication dropadmindb on each subscriber one by one and then the publisher, then utils dbreplication reset all on the publisher only.disputed
    Troubleshoot CUCM Database Replication Issues · Step 8. Reset the Database Replication from Scratch · Checked 2026-09-30
  34. 34
    The technote attributes one class of replication-related network diagnostic error to a failed reverse DNS lookup on a node, and checks it with utils network eth0 all and utils network host.
    Troubleshoot CUCM Database Replication Issues · Step 4. Check the Individual Components that Use the Utils Diagnose Test Command, Network Connectivity · Checked 2026-09-30
  35. 35
    In the Release 15 CLI reference, utils dbreplication runtimestate requires command privilege level 0, is allowed during upgrade, and when given a node name reports the replication state from the context of that node.
    Command Line Interface Reference Guide for Cisco Unified Communications Solutions, Release 15 and SUs - Utils Commands · utils dbreplication runtimestate > Usage Guidelines and Requirements · Checked 2026-09-30
  36. 36
    The health-check technote lists four services that must show STARTED in utils service list for replication: Cluster Manager, A Cisco DB, A Cisco DB Replicator and Cisco Database Layer Monitor.
    Perform a Health Check of CUCM Database Replication · Services Verification · Checked 2026-09-30
  37. 37
    When show network cluster on a subscriber shows incorrect publisher information after an address change, the Administration Guide corrects it with set network cluster publisher.
  38. 38
    utils dbreplication setprocess accepts a value from 1 to 40 (default 1); raising it improves replication setup performance but consumes additional system resources.
    Command Line Interface Reference Guide for Cisco Unified Communications Solutions, Release 15 and SUs - Utils Commands · utils dbreplication setprocess > Syntax Description and Usage Guidelines · Checked 2026-09-30
  39. 39
    When reading runtimestate, the technote tells you to check the timestamp so that the Cluster Replication State section is not read from old sync information.
    Troubleshoot CUCM Database Replication Issues · Step 1. Verify Database Replication is Broken · Checked 2026-09-30
  40. 40
    The Release 15 Administration Guide defines replication setup value 0 as replication not started, because either no subscribers exist or the Database Layer Monitor service has not been running.
    Administration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Troubleshooting Address Change Issues · Troubleshoot Database Replication > Verify Database Replication, value table, row 0 · Checked 2026-09-30
  41. 41
    The TAC troubleshooting technote describes state 0 as an initialization state in which replication is being set up, and says a setup failure can have occurred if a node stays in that state for more than an hour.
    Troubleshoot CUCM Database Replication Issues · Step 1. Verify Database Replication is Broken, state table, value 0 · Checked 2026-09-30
  42. 42
    Replication setup value 1 means replicates have been created but their count is incorrect.
    Administration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Troubleshooting Address Change Issues · Troubleshoot Database Replication > Verify Database Replication, value table, row 1 · Checked 2026-09-30
  43. 43
    In the Replication Setup (RTMT) & Details column of utils dbreplication runtimestate, a value of 2 means replication is good.
    Administration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Troubleshooting Address Change Issues · Troubleshoot Database Replication > Verify Database Replication, value table, row 2 · Checked 2026-09-30
  44. 44
    The Release 15 Administration Guide defines replication setup value 3 as replication being bad in the cluster.
    Administration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Troubleshooting Address Change Issues · Troubleshoot Database Replication > Verify Database Replication, value table, row 3 · Checked 2026-09-30
  45. 45
    The TAC troubleshooting technote describes state 3 as mismatched tables: logical connections are established but it is uncertain whether the tables match.
    Troubleshoot CUCM Database Replication Issues · Step 1. Verify Database Replication is Broken, state table, value 3 · Checked 2026-09-30
  46. 46
    The Release 15 Administration Guide defines replication setup value 4 as replication setup not having succeeded.
    Administration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Troubleshooting Address Change Issues · Troubleshoot Database Replication > Verify Database Replication, value table, row 4 · Checked 2026-09-30
  47. 47
    The TAC troubleshooting technote describes state 4 as setup failed or dropped: the server no longer has an active logical connection over which to receive database tables.
    Troubleshoot CUCM Database Replication Issues · Step 1. Verify Database Replication is Broken, state table, value 4 · Checked 2026-09-30
  48. 48
    utils dbreplication status starts a background check of replication, and its progress and result are read with utils dbreplication runtimestate.
    Perform a Health Check of CUCM Database Replication · Database Commands · Checked 2026-09-30
  49. 49
    The Release 15 CLI reference says utils dbreplication status should be run only on the first node (publisher) of a cluster, and it is not allowed during upgrade.
    Command Line Interface Reference Guide for Cisco Unified Communications Solutions, Release 15 and SUs - Utils Commands · utils dbreplication status > Usage Guidelines and Requirements · Checked 2026-09-30
  50. 50
    The Administration Guide and the CLI reference both say that before utils dbreplication reset is run, utils dbreplication stop must first be run on all subscriber nodes.
    Administration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Troubleshooting Address Change Issues · Troubleshoot Database Replication > Reset Database Replication, note before Step 1 · Checked 2026-09-30
  51. 51
    If the servers in a cluster are switched back to an older product release, the Release 15 upgrade guide requires database replication to be reset manually by running utils dbreplication reset all from the publisher CLI.
  52. 52
    For a TAC replication case, Cisco asks for utils dbreplication runtimestate from the publisher, plus show network cluster, show status, utils diagnose test, utils service list, utils network connectivity, show open ports all and show open ports regexp 8500 from the publisher and each affected subscriber, plus the Unified CM Database Status report.
    CUCM Database Replication Issues · Information to Collect · Checked 2026-09-30
  53. 53
    The technote says to consult Cisco TAC before running its repair and reset steps (Steps 7 and 8) on clusters with more than 8 nodes.
    Troubleshoot CUCM Database Replication Issues · Step 7. Repair All/Selective Tables for Database Replication, note · Checked 2026-09-30
  54. 54
    The health-check technote reads the system history log for ungraceful shutdowns, which appear as consecutive Boot entries with no Restart entry between them, and suggests rebuilding a server after such an event.
    Perform a Health Check of CUCM Database Replication · System History Log File · Checked 2026-09-30
  55. 55
    The 0 to 4 replication setup value definitions in the Administration Guide read the same in the 12.5(1)SU1 and Release 15 editions, so the state meanings appear not to have changed between those releases.inferred
    Administration Guide for Cisco Unified Communications Manager, Release 12.5(1)SU1 - Troubleshooting Address Change Issues · Troubleshoot Database Replication > Verify Database Replication, value table · Checked 2026-09-30
  56. 56
    To verify replication, the Administration Guide has you run utils dbreplication runtimestate on the first node and confirm that each node shows a Connected replication status and a setup value of (2) Setup Completed.
    Administration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Troubleshooting Address Change Issues · Troubleshoot Database Replication > Verify Database Replication, Steps 1-2 · Checked 2026-09-30
  57. 57
    For Out of Sync or Not Requested statuses on nodes spread across a WAN, the technote says to ensure the nodes have network connectivity well under 80 ms.
    Troubleshoot CUCM Database Replication Issues · Step 6. The Utils Dbreplication Runtimestate Command Shows out of Sync or not Requested Statuses · Checked 2026-09-30

Documents

tier 2 current vendor documentation

Administration Guide for Cisco Unified Communications Manager, Release 12.5(1)SU1 - Troubleshooting Address Change Issues

Cisco Systems · 2025-04-08 · accessed 2026-09-30

tier 2 current vendor documentation

Administration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Pre-Change Tasks and System Health Checks

Cisco Systems · 2026-08-31 · accessed 2026-09-30

tier 2 current vendor documentation

Administration Guide for Cisco Unified Communications Manager, Release 15 and SUs - Troubleshooting Address Change Issues

Cisco Systems · 2026-08-31 · accessed 2026-09-30

tier 2 current vendor documentation

CUCM Database Replication Issues

Cisco Systems · 2018-09-14 · accessed 2026-09-30

tier 2 current vendor documentation

Perform a Health Check of CUCM Database Replication

Cisco Systems · 2025-07-17 · accessed 2026-09-30

tier 2 current vendor documentation

Troubleshoot CUCM Database Replication Issues

Cisco Systems · 2025-12-03 · accessed 2026-09-30

Cite this page

APA

WarmTransfer. (2026, September 30). Troubleshooting Unified CM database replication. WarmTransfer. https://warmtransfer.net/knowledge/cucm-database-replication-troubleshooting

BibTeX

@misc{warmtransfer-cucm-database-replication-troubleshooting,
  title  = {Troubleshooting Unified CM database replication},
  author = {{WarmTransfer}},
  year   = {2026},
  url    = {https://warmtransfer.net/knowledge/cucm-database-replication-troubleshooting},
  note   = {Verified 2026-09-30}
}