Source record · tier 2 current vendor documentation
Troubleshoot PDD in Webex Calling with Premises Based PSTN
- Publisher
- Cisco Systems
- URL
- https://www.cisco.com/c/en/us/support/docs/unified-communications/jabber-windows/221643-troubleshoot-pdd-in-webex-calling-with-p.html
- Published
- 2024-02-06
- Updated
- unknown
- Accessed
- 2026-09-25
- HTTP status
- 200
- License
- Cisco website terms of use; all rights reserved; no-redistribution; short excerpts and locators only
Source notes citing this source
- As of a February 2024 TAC technote, when a premises PSTN provider behind a Local Gateway takes more than 12 seconds of post-dial delay, Webex Calling cancels the call. in context
- The same technote says that extending the 12-second post-dial delay limit requires opening a Webex Calling TAC case with Local Gateway traces (debug ccsip messages and debug voice ccapi inout). in context
- The TAC procedure for collecting Local Gateway call traces enables debug ccsip messages and debug voice ccapi inout, logs to a large debug-level buffer, and turns off console and monitor logging and logging rate and queue limits. in context
- With premises-based PSTN, if the PSTN provider's post-dial delay exceeds 12 seconds, Webex Calling automatically cancels the call. in context
- To get the PDD limit extended beyond 12 seconds, TAC advises opening a Webex Calling support case with Local Gateway traces attached. in context
Cite this source record
APA
WarmTransfer. (2024, February 6). Troubleshoot PDD in Webex Calling with Premises Based PSTN. WarmTransfer. https://warmtransfer.net/knowledge/sources/cisco-technote-221643-wxc-pdd-premises-pstn
BibTeX
@misc{warmtransfer-cisco-technote-221643-wxc-pdd-premises-pstn,
title = {Troubleshoot PDD in Webex Calling with Premises Based PSTN},
author = {{WarmTransfer}},
year = {2024},
url = {https://warmtransfer.net/knowledge/sources/cisco-technote-221643-wxc-pdd-premises-pstn},
note = {Cisco Systems, accessed 2026-09-25}
}