Source record · tier 2 current vendor documentation
Get started with your new Cisco IP DECT 6800 series
- Publisher
- Cisco Webex
- URL
- https://help.webex.com/en-us/article/nq28lbi/Get-Started-with-Your-New-Cisco-IP-DECT-6800-Series
- Published
- 2025-06-05
- Updated
- unknown
- Accessed
- 2026-09-24
- HTTP status
- 200
- License
- Cisco copyright; all rights reserved; no-redistribution; short excerpts and locators only
Source notes citing this source
- Cisco's getting-started sequence is: charge handsets, collect handset IPEI numbers and user data, do a site survey, install and power the base station, let it auto-configure, configure handsets on the base station web page, register handsets, then hand them out. in context
- A handset is registered to a base station from the handset menu at Connectivity > Register, choosing an empty registration row and entering the access code if prompted. in context
- A multi-cell DBS-210 system supports a maximum of 250 base stations, or 50 base stations plus 100 repeaters. disputed in context
- Cisco says a repeater extends base station range by up to 984 feet outdoors or 164 feet indoors. in context