Source note · Troubleshooting DECT handsets on Webex Calling
When the Multi Cell page shows Searching! in the DECT property column, the bases cannot communicate; move the base closer (about -75 dBm signal recommended) or add a base in between, and check for interference.
Checked 2026-10-02
The base stations can't communicate.
- Vendor
- Cisco
- Product
- Cisco IP DECT 6800 Series
- Subsystem
- DECT multi-cell sync
- Deployment
- multi-tenant, on-premises
- Region
- not restricted
- Release range
- current as of 2026-10-02
- Checked
- 2026-10-02
Sources
- Cisco IP DECT 6800 Series Administration Guide - Troubleshooting — Cisco Systems · tier 2 current vendor documentation · Multicell Troubleshooting > Base Station Shows Searching in DECT Property