Source record · tier 2 current vendor documentation
Configuring SIP Interfaces (Mediant Software SBC User's Manual Version 7.6)
- Publisher
- AudioCodes
- URL
- https://techdocs.audiocodes.com/session-border-controller-sbc/mediant-software-sbc/user-manual/version-760/Content/UM/Configuring%20SIP%20Interfaces.htm
- Published
- unknown
- Updated
- unknown
- Accessed
- 2026-09-24
- HTTP status
- 200
- License
- AudioCodes copyright; all rights reserved; no-redistribution; short excerpts and locators only
Source notes citing this source
- The SIP Interface 'Classification Failure Response Type' sets the SIP response sent when classification fails; the default is 500, valid values are 400 to 699, and 0 sends no response, which helps against DoS. in context
- A SIP Interface represents a Layer-3 network by defining a local listening port and transport type and assigning an IP network interface for SIP signaling. in context
- Each SIP Interface can be associated with only one SRD; in single-SRD deployments SIP Interfaces go to the default SRD automatically. in context
Cite this source record