Source record · tier 2 current vendor documentation
Configuring Log Filter Rules (Mediant Software SBC User's Manual Version 7.6)
- Publisher
- AudioCodes
- URL
- https://techdocs.audiocodes.com/session-border-controller-sbc/mediant-software-sbc/user-manual/version-760/Content/UM/Configuring%20Log%20Filter%20Rules.htm
- Published
- unknown
- Updated
- unknown
- Accessed
- 2026-09-24
- HTTP status
- 200
- License
- AudioCodes copyright; all rights reserved; no-redistribution; short excerpts and locators only
Source notes citing this source
- A logging filter can send its output to a syslog server, a debug recording server, local storage on the device, or OVOC (for quality-of-experience data), with log types of Signaling, Signaling & Media, or Signaling & Media & PCM. in context
- The Logging Filters table holds up to 60 rules, and filters can target calls by criteria such as Any, IP Group, SRD, Classification, IP-to-IP Routing, User, SIP Interface or IP Trace. in context
- AudioCodes warns that media debug recording needs a lot of device resources and that, when many media sessions are selected, not all sessions and their signaling will be recorded. in context
Cite this source record
APA
WarmTransfer. (2026, September 24). Configuring Log Filter Rules (Mediant Software SBC User's Manual Version 7.6). WarmTransfer. https://warmtransfer.net/knowledge/sources/audiocodes-swsbc-um76-logging-filters
BibTeX
@misc{warmtransfer-audiocodes-swsbc-um76-logging-filters,
title = {Configuring Log Filter Rules (Mediant Software SBC User's Manual Version 7.6)},
author = {{WarmTransfer}},
year = {2026},
url = {https://warmtransfer.net/knowledge/sources/audiocodes-swsbc-um76-logging-filters},
note = {AudioCodes, accessed 2026-09-24}
}