For an agent using a PSTN number, the older station credentials screen needs Dial Number selected, International Dialing Format checked and the correct country code chosen. Leaving these out can cause immediate RONA when a call is offered.
Checked 2026-09-30
- Vendor
- Cisco
- Product
- Webex Contact Center
- Subsystem
- Station login / Dial Number
- Deployment
- multi-tenant
- Region
- not restricted
- Release range
- as printed 2025-02-10; station credentials UI before the 2025-10-29 redesign
- Checked
- 2026-09-30
Sources
- Troubleshoot RONA Issue When Agents Enter Dial Number in Wrong Tab — Cisco Systems (Webex Help Center) · tier 2 current vendor documentation · Troubleshoot RONA Issue When Agents Enter Dial Number in Wrong Tab > Solution > PSTN numbers
Cite this note
APA
WarmTransfer. (2026, September 30). Troubleshooting Webex Contact Center Agent Desktop sign-in and station login: source note wxcc-agent-login-troubleshooting-pstn-intl-format. WarmTransfer. https://warmtransfer.net/knowledge/claims/wxcc-agent-login-troubleshooting-pstn-intl-format
BibTeX
@misc{warmtransfer-claim-wxcc-agent-login-troubleshooting-pstn-intl-format,
title = {Troubleshooting Webex Contact Center Agent Desktop sign-in and station login: source note wxcc-agent-login-troubleshooting-pstn-intl-format},
author = {{WarmTransfer}},
year = {2026},
url = {https://warmtransfer.net/knowledge/claims/wxcc-agent-login-troubleshooting-pstn-intl-format},
note = {Source note wxcc-agent-login-troubleshooting-pstn-intl-format, checked 2026-09-30}
}