Source note · SIP trunk carrier turn-up and acceptance testing
When MaxConcurrentSessions is set on a Direct Routing SBC, the alerting system notifies at 90 percent or more of the value; if it is unset, no alerts are generated.
Checked 2026-09-25
- Vendor
- Microsoft
- Product
- Teams Phone Direct Routing
- Subsystem
- capacity
- Deployment
- multi-tenant
- Region
- not restricted
- Release range
- current as of 2026-09-25
- Checked
- 2026-09-25
Sources
- Connect your Session Border Controller (SBC) to Direct Routing — Microsoft · tier 2 current vendor documentation · SBC settings table, MaxConcurrentSessions row