Source note · Message waiting indicator troubleshooting
For some phone systems integrated through PIMG/TIMG units, Unity Connection must turn an MWI off on the same port that turned it on; if a different port is used, the MWI-off request fails and the MWI stays on.
Checked 2026-09-25
the MWI request for turning off the MWI fails
- Vendor
- Cisco
- Product
- Cisco Unity Connection
- Subsystem
- PIMG/TIMG integrations
- Deployment
- on-premises
- Region
- not restricted
- Release range
- Unity Connection Release 14 and 15
- Checked
- 2026-09-25
Sources
- Troubleshooting Guide for Cisco Unity Connection Release 14 - Troubleshooting Message Waiting Indicators (MWIs) — Cisco Systems · tier 2 current vendor documentation · MWI Problems > MWIs Turn On but Do Not Turn Off