Source note · Troubleshooting Cisco Finesse agent sign-in
For UCCX agent sign-in, Maximum Number of Calls and Busy Trigger on the agent line should be set to 2 and 1 respectively.
Checked 2026-10-02
- Vendor
- Cisco
- Product
- Cisco Unified Contact Center Express
- Subsystem
- Unified CM line configuration
- Deployment
- on-premises
- Region
- not restricted
- Release range
- UCCX releases covered by technote 210485
- Checked
- 2026-10-02
Sources
- Troubleshoot Agent Log in Issues — Cisco Systems (TAC technote) · tier 2 current vendor documentation · Problem 1, cause 6 (call settings)