Source note · Troubleshooting Expressway business-to-business calls
The SDL error 'Ignoring large message. Only allow up to 5000 bytes. Resetting connection.' on B2B video calls is fixed by raising the Unified CM CallManager service parameter SIP Max Incoming Message Size from 5000 to 11000 bytes.
Checked 2026-10-02
- Vendor
- Cisco
- Product
- Unified Communications Manager
- Subsystem
- CallManager service parameters
- Deployment
- on-premises
- Region
- not restricted
- Release range
- systems upgraded from Unified CM 8.6 or earlier that retained the 5000-byte value
- Checked
- 2026-10-02
Sources
- Troubleshoot Most Common Issues for Business to Business Calls Through Expressway — Cisco Systems · tier 2 current vendor documentation · Problem section 'Error //SIP/SIPTcp/wait_SdlReadRsp: Ignoring large message'