Source note · Troubleshooting Expressway business-to-business calls
Unified CM dropping the TCP session on inbound B2B calls is caused by a mismatch between the Expressway-C neighbor zone destination port and the incoming port of the Unified CM SIP trunk security profile; MRA and B2B cannot share 5060/5061, so both sides must use the same custom port.