Unified CM dropping the TCP session on inbound B2B calls is caused by a mismatch between the Expressway-C neighbor zone destination port and the incoming port of the Unified CM SIP trunk security profile; MRA and B2B cannot share 5060/5061, so both sides must use the same custom port.

Checked 2026-10-02

Vendor
Cisco
Product
Expressway
Subsystem
neighbor zone
Deployment
on-premises
Region
not restricted
Release range
as stated in 2018 technote
Checked
2026-10-02

Sources

Cite this note

APA

WarmTransfer. (2026, October 2). Troubleshooting Expressway business-to-business calls: source note expressway-b2b-troubleshooting-cucm-tcp-drop-port-mismatch. WarmTransfer. https://warmtransfer.net/knowledge/claims/expressway-b2b-troubleshooting-cucm-tcp-drop-port-mismatch

BibTeX

@misc{warmtransfer-claim-expressway-b2b-troubleshooting-cucm-tcp-drop-port-mismatch,
  title  = {Troubleshooting Expressway business-to-business calls: source note expressway-b2b-troubleshooting-cucm-tcp-drop-port-mismatch},
  author = {{WarmTransfer}},
  year   = {2026},
  url    = {https://warmtransfer.net/knowledge/claims/expressway-b2b-troubleshooting-cucm-tcp-drop-port-mismatch},
  note   = {Source note expressway-b2b-troubleshooting-cucm-tcp-drop-port-mismatch, checked 2026-10-02}
}

Read in context