Source note · Troubleshooting UCCE and CVP call failures
For the comprehensive model, CVP's Maximum Length of DNIS is set to the length of the network routing number; with a gateway pattern of 1800 followed by six digits, it is 10.
Checked 2026-10-02
- Vendor
- Cisco
- Product
- Unified CVP
- Subsystem
- comprehensive call flow
- Deployment
- on-premises
- Region
- not restricted
- Release range
- Unified CVP 12.5(1)
- Checked
- 2026-10-02
Sources
- Configuration Guide for Cisco Unified Customer Voice Portal, Release 12.5(1) - Unified CVP Call Flow Models — Cisco Systems · tier 2 current vendor documentation · Set Up Comprehensive Call Flow Model Using SIP for ICME and ICMH